Network PA System 16‑Zone Matrix with Monitor OBT-8016
Network PA System 16‑Zone Matrix with Monitor OBT-8016
Network PA System 16‑Zone Matrix with Monitor OBT-8016
Network PA System 16‑Zone Matrix with Monitor OBT-8016
Network PA System 16‑Zone Matrix with Monitor OBT-8016
Network PA System 16‑Zone Matrix with Monitor OBT-8016
$0
EXW
배송 방법:
快递
제품 소개:

Network PA System – 16‑Zone Matrix with Monitor (2U, 4 Background + 4 Alarm Inputs, Built‑in Speaker)
Features:
- High‑grade aluminum 2U black anodized brushed panel, elegant and stylish.
- 16‑zone paging selection function.
- All‑zone on/off function, for quick control of 16‑channel output.
- Zone alarm activation function, for emergency fire broadcast.
- 4‑channel background music input, 4‑channel alarm sound source input.
- 16‑channel monitoring channel indicator lights, for real‑time monitoring status check.
- 16‑channel paging indicator lights, for clear display of each channel's working status.
- Built‑in high‑fidelity 5W/8Ω full‑range monitoring speaker.
- Adjustable monitoring volume.
This **Network PA System** zone matrix allows flexible routing of background music and emergency signals to 16 independent zones, with built‑in monitoring for real‑time verification.
Technical Specifications:
- Group A1 Input: 70V/100V, audio signal "CH1‑CH4".
- Group A2 Input: 70V/100V, audio signal "CH5‑CH8".
- Group A3 Input: 70V/100V, audio signal "CH9‑CH12".
- Group A4 Input: 70V/100V, audio signal "CH13‑CH16".
- Group B1 Input: 70V/100V, emergency broadcast (alarm) audio signal "CH1‑CH4".
- Group B2 Input: 70V/100V, emergency broadcast (alarm) audio signal "CH5‑CH8".
- Group B3 Input: 70V/100V, emergency broadcast (alarm) audio signal "CH9‑CH12".
- Group B4 Input: 70V/100V, emergency broadcast (alarm) audio signal "CH13‑CH16".
- Monitorable Lines: 16 channels "CH1~CH16".
- Monitoring Speaker: Built‑in high‑fidelity "HiFi" full‑range speaker, 5W.
- Zone Input Capacity: Total audio signal input capacity: 4kW; average load capacity per zone: 250W; total emergency broadcast (alarm) audio signal input capacity: 4kW; average load capacity per zone: 250W.
- Alarm Activation Input: (0V) short‑circuit signal (ALARM IN).
- Alarm Activation Output: (0V) 2‑way short‑circuit signal (ALARM OUT).
- Protection: AC FUSE × 0.5A.
- Power Supply: AC 220V ± 10% 50‑60Hz.
- Power Consumption: 15‑20W.
- Machine Dimensions: 89 × 483 × 366 mm.
- Net Weight: 6.8Kg.
In summary, this **Network PA System** 16‑zone matrix with monitor, dual audio source groups, and alarm integration is the ideal choice for schools, hospitals, hotels, and large commercial buildings requiring reliable zone‑based public address and emergency broadcasting.

자세히 보기:
제품 세부정보
필수 정보
납기일:5-7天
배송 방법:快递
제품 소개

Network PA System – 16‑Zone Matrix with Monitor (2U, 4 Background + 4 Alarm Inputs, Built‑in Speaker)
Features:
- High‑grade aluminum 2U black anodized brushed panel, elegant and stylish.
- 16‑zone paging selection function.
- All‑zone on/off function, for quick control of 16‑channel output.
- Zone alarm activation function, for emergency fire broadcast.
- 4‑channel background music input, 4‑channel alarm sound source input.
- 16‑channel monitoring channel indicator lights, for real‑time monitoring status check.
- 16‑channel paging indicator lights, for clear display of each channel's working status.
- Built‑in high‑fidelity 5W/8Ω full‑range monitoring speaker.
- Adjustable monitoring volume.
This **Network PA System** zone matrix allows flexible routing of background music and emergency signals to 16 independent zones, with built‑in monitoring for real‑time verification.
Technical Specifications:
- Group A1 Input: 70V/100V, audio signal "CH1‑CH4".
- Group A2 Input: 70V/100V, audio signal "CH5‑CH8".
- Group A3 Input: 70V/100V, audio signal "CH9‑CH12".
- Group A4 Input: 70V/100V, audio signal "CH13‑CH16".
- Group B1 Input: 70V/100V, emergency broadcast (alarm) audio signal "CH1‑CH4".
- Group B2 Input: 70V/100V, emergency broadcast (alarm) audio signal "CH5‑CH8".
- Group B3 Input: 70V/100V, emergency broadcast (alarm) audio signal "CH9‑CH12".
- Group B4 Input: 70V/100V, emergency broadcast (alarm) audio signal "CH13‑CH16".
- Monitorable Lines: 16 channels "CH1~CH16".
- Monitoring Speaker: Built‑in high‑fidelity "HiFi" full‑range speaker, 5W.
- Zone Input Capacity: Total audio signal input capacity: 4kW; average load capacity per zone: 250W; total emergency broadcast (alarm) audio signal input capacity: 4kW; average load capacity per zone: 250W.
- Alarm Activation Input: (0V) short‑circuit signal (ALARM IN).
- Alarm Activation Output: (0V) 2‑way short‑circuit signal (ALARM OUT).
- Protection: AC FUSE × 0.5A.
- Power Supply: AC 220V ± 10% 50‑60Hz.
- Power Consumption: 15‑20W.
- Machine Dimensions: 89 × 483 × 366 mm.
- Net Weight: 6.8Kg.
In summary, this **Network PA System** 16‑zone matrix with monitor, dual audio source groups, and alarm integration is the ideal choice for schools, hospitals, hotels, and large commercial buildings requiring reliable zone‑based public address and emergency broadcasting.

관련 상품

OBT-9800_6.jpg
OBT-9928-21.jpg
OBT-POE611_2-021.jpg
OBT-NP903_3-02.png

OBT-9800

OBT-9928

OBT-POE611

OBT-NP903

SHENZHEN OBTPA TECHNOLOGY CO.,LTD

담당자: John Chen

이메일: John@obtpa.com

광동성 불산시 순덕구 준안진 지안북로 16번, 시유남원 10동 402호.

문의하기

WhatsApp
위챗
지메일
페이스북